FD 60 B-F / FD 60 B-C

Diesel generators

22.0 kVA - 66.0 kVA

Ask about this generator

Contact us

Features of the unit

Engine Baudouin 4M10G70/5
Exhaust emissions fuel optimized
Fuel system direct injection
Speed regulation electronic
Frequency 50Hz
ESP maximum power 66.0 kVA / 53.0 kW
PRP rated power 60.0 kVA / 48.0 kW
Fuel tank 260 L
Alternator Leroy Sommer TAL 042 H
Performance class G3 (wg ISO 8528-5)

Characteristics

  • Digital voltage regulation +/-0.25%
  • Three-phase voltage control
  • Low disturbance level THD <2%
  • Alternator short circuit capacity 270 % In (optional 300 %)
  • Class H insulation
  • Protection index IP23
  • Performance class G3 (acc. ISO 8528-5)
  • Ready to load just after start
  • AMF and MRS functionality and protection
  • Autonomy 21,0 h with 75 % load
  • Compact design
  • Forklift manouvable from the front and side wall

ComAp driver

InteliLite AMF 25

  •  Controller type: ComAp InteliLite AMF 25
  •  Support of Dual AMF/MRS applications
  •  Direct communication with EFI engines
  •  Total remote monitoring and control
  •  Intuitive operator interface, adjustable Main Screen
  •  Real time clock
  •  Comprehensive history log with up to 350 events
  •  3 phase true RMS current and voltage measurement
  •  Both mains and generator voltage detection
  •  Active/Reactive Power and Power Factor per phase measurement
  •  Run Hours counter with source selector
  •  3 maintenance timers (counting even under zero)
  •  Multipurpose flexible timers (also for rental)
  •  Battery voltage measurement
  •  Complete engine and alternator protection
  •  CAN modules support
  •  USB port on-board
  •  2 slots for plug-in modules
  •  Plug-in module concept for more capabilities (RS232, RS485, Ethernet, GPRS, 4G/LTE, Modbus, SNMP, emails, SMS, I/Os)
  •  Cloud-based monitoring and control via WebSupervisor) (optional module required)
  •  Geofencing and tracking via WebSupervisor (optional module required)
  •  Control and monitoring over SMS (GSM module required)
  •  3 levels of password protection
  •  In-built PLC, complemented with a monitoring/debugging tool, for additional functionality, if required
  •  Spare inputs and outputs available by default: binary input – 2, binary output – 1, analogue input – 3,
  •  A version for low temperature is also available

Baudouin engine

4M10G70/5

Manufacturer Baudouin
Type 4M10G70/5
Made in China
Engine power 57,0 kW
Emission standard non-emission
Rotation per minute 1500 rpm
Engine governor electronic
Governor class G3 (wg ISO 8528-5)
Displacement 4,1 l
No of cylinder 4
Fuel system direct injection
Electrical system 12 V
Cooling system capacity 18,0 l
Oil pan capacity 14,0 l
Fuel type Diesel (EN 590)

Leroy Somer alternator

TAL 042 H

Manufacturer Leroy Somer
Type TAL 042 H
Made in The czech republic
Nominal voltage 400 V
Nominal power factor (cos φ) 0,8
Ambient temperature, altitude 40 ºC, 1000m n.p.m.
Nominal Power 60.0 kVA
Protection index IP 23
No of bearing single bearing
Coupling direct
Technology brushless
Short circuit maintaining capacity 270% 10s
Efficiency 89,9 %
Insulation class H
Total harmonic content THD <2 %
Reactance Xd'' 7,3 %
Voltage regulator type AVR, digital
Voltage measurement 3 phases
Adjustment accuracy +/- 0,25 %
AVR Power Supply AREP+
AVR supply optional PMG
Share by: